Notes on DSP diagnosis
You can use the trace function built into the TMAMF module to diagnose malfunctions or obtain
more precise error analysis. The subminiature D connector provides information about MFC-
R2 signaling. To activate the trace function, you must connect a PC with a terminal emulation
program (such as Microsoft HyperTerminal).
Terminal configuration:
Bits per second = 19,200
Data bits = 8
Stop bit = 1
Parity = none
Flow control = none
Pin assignments of the diagnostic cable