Siemens HiPath 5000 Service Manual page 1024

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

service.fm
Service
Guided Maintenance
Table 12-8
Event Viewer Entries for the HiPath 5000 Server
Event
De-
Error text
fault
trap
1036
X
CDB trans-
fer from
(<IP-Adr>)
failed
(read)
1037
Interface
error (_hr=
0xzzzzzzzz
z)
1038
User inter-
face active
on <IP-
Adr>
1039
User:
"<user-
name>" on
PC:
"<pc_name
>": read
CDB data
from server
12-62
Meaning
Data reading
Save event
from HiPath
file for error
3000/5000 (with
analysis
specified IP ad-
dress in the
server) failed
If 0xzzzzzzz =
Save event
0x80070057,
file for error
this is just inter-
analysis
nal information
for Develop-
ment, otherwise
error
The user inter-
face is active
during a sync.
Trials are not
cancelled and
are cyclically re-
peated until
successful.
HiPath 3000
Manager E in-
formation about
user actions,
user reads data
from the server.
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
User reaction
Check HiPath 3000/
5000. Check
HG 1500. Check
LAN. Initiate HiPath
3000/5000 ping, if
necessary.
Activate HiPath
3000/5000 data
loading via HiPath
3000 Manager E.
If an error message
appears, RgTrace-
File.txt and Carlog
File must be saved.
Information
Information
P31003-H3560-S403-54-7620, 09/05
Cate-
Source
gory
vsrv HiPath
AllServ
e
reg
HiPath
AllServ
e
sync HiPath
AllServ
e
vsr-
HiPath
vad-
AllServ
min
e

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents