Siemens HiPath 5000 Service Manual page 1018

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

service.fm
Service
Guided Maintenance
Table 12-7
HiPath 3000 Class B Error Messages
No.
35
No ELIC interrupts
36
SDRAM: Access to protected area
37
SDRAM: Write error, wrong address
38
SDRAM: Read error, wrong address
Error Class B-30 - Firmware/Loadware
6
HDLC Controller Error on board
Error Class B-40 - MMC
0
MMC defective
Error Class B-41 - LAN
4
Send: Ethernet driver not ready
8
Send: More than 15 futile attempts
9
Send: Delayed collision detection
10
Send: Carrier loss
11
Receive: Frame error
12
Receive: FIFO error
13
Receive: Checksum error
14
Receive: Defective receiving buffer
15
Receive: Frame too short
16
Receive: Frame too long
17
Receive: Delayed collision detection
18
Receive: Partial deletion of data due to the
existing write protection
12-56
Meaning
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Action
Recovery
Hard restart
Notify appropriate service
Hard restart
Hard restart
Reload board
Hard restart
For errors that appear
sporadically, no action is
For errors that appear reg-
ularly, replace the LIM
module. If this does not
correct the error, check
the LAN configuration.
P31003-H3560-S403-54-7620, 09/05
Action
Technician
support
Replace board
Replace MMC
necessary.