Siemens HiPath 5000 Service Manual page 213

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

Lockout switch settings
Pressed = free (default)
Not pressed = locked: existing connections remain active, new connections are locked.
The yellow LED lights up when all connections are ended and the board is effectively
locked.
The yellow LED flashes when a lockout request is entered (via lockout switch or soft-
ware) but at least one call is still active.
To reset the board to the default state, activate the lockout switch four times (off-on-off-on) dur-
ing the LED test. This action cancels the LED test and both LEDs flash for approximately
five seconds in confirmation.
LED statuses and their meanings
Table 3-49
IVMNL/IVMN8 - LED Statuses
LED
Green
Red
LED
During Startup and Initialization
Off
Off
On
On
On
Off
Off
Flashing
Off
(500/
500 ms)
Off
On
On
Off
During Operation
Off
On
Off
Flashing
(500/
500 ms)
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Meaning
1 Boot procedure (lasts approx. 8 -
12 s)
2 LED test (lasts approx. 10 s)
3 Lockout switch state signaling by
red LED (lasts approx. 5 s):
blocked = On
free = Off
4 Hard disk test, start of the applica-
tion (depending on hard disk sta-
tus, lasts approx. 3 - 8 minutes)
5a Standby mode after successful
boot
5b Board locked or board error oc-
curred
Idle (no call)
At least one active port (call)
Boards for HiPath 3000
Peripheral Boards
Action
Possibly check if board was de-
activated using HiPath 3000
Manager E or lockout switch.
Check whether board was deacti-
vated using HiPath 3000 Manag-
er E or lockout switch.
boards.fm
3-123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents