Siemens HiPath 5000 Service Manual page 623

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

If
Slot with any
Route 16 TW to the patch panel (S30807-K6143-X) via SU Xx8 using a CA-
other periph-
BLU.
eral board
Part number for CABLU with 16 TW:
Assignment
Route the REAL board via an S
with
are routed to (and manually laid at) the S
REAL
using an open-end cable.
Part numbers for open-end cable:
1
A CABLU with 16 TW is also sufficient for these boards. A CABLU with 24 TW is recommended to simplify station config-
uration expansion (for example, by replacing the SLMO8 by an SLMO24).
For U.S. only: CABLUs for the slots containing peripheral boards
If
Slot with 24-port
Route 16 TW to the patch panel via SU Xx8 and 8 TW via SU Xx9, using
peripheral
standard CABLU S30267-Z365-A30 (SU connectors are labeled "8" and
boards
"9"). Both cables are connected to the same 50-pin Champ jack.
Slot with 16-port
Route 16 TW to the main distribution frame via SU Xx8 using standard CA-
peripheral
BLU S30267-Z365-A30.
boards
Slot with TMST1 T1 connections (see Section 3.3.41, "TMST1 (for U.S. only)") are not set up
via the main distribution frame.
An adapter (1 SU connector - 8-pin MW8 (RJ48C) jack, Figure 4-86) is con-
nected directly to the SU Xx9 backplane connector. You can use a special
cable to create a direct connection to the CSU or networked system.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
S30267-Z362-A20: 2 m in length
S30267-Z192-A60: 6 m in length
S30267-Z192-A100: 10 m in length
S30267-Z192-A200: 20 m in length
Installing HiPath 3750, HiPath 3700
Then
patch panel (C39104-Z7001-B3). The 16 TW
0
patch panel via SU X6 (backplane)
0
Then
inst_h3.fm
Installing HiPath 3000
4-145