Testing Telephones; Table 12-6 Terminal Test; Eventlog For Hipath 3000 - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

12.3.1.7

Eventlog for HiPath 3000

HiPath 3000 features an eventlog where accrued errors are classified according to error class
and error number with the date/time of the original error. You can use HiPath 3000 Manager E
to read out the eventlog.
Section 12.3.2 contains information on the possible entries.
12.3.1.8

Testing Telephones

After startup and country adaptation, you can activate the terminal test on any
optiPoint 600 office, optiPoint 410, and optiPoint 420 telephone using a code or the service
menu.
It is not possible to perform the terminal test on optiPoint 410 S and optiPoint 420 S telephones.
This test checks the display (your number is displayed), LEDs, and ring tones. The tests ends
automatically after a period of time. The test allows you to perform a visual and acoustic check
of the components to ensure that they are functioning properly.
Test procedure on the system telephone
Table 12-6
Terminal Test
Step
1.
2.
If the test does not react as described, an additional power supply (plug-in power
>
supply unit) for the relevant system telephone may be necessary.
The phone number, date and time are normally shown in the display. If a different text appears
("Gateway not found", for example), this means that there is an error.
Correct the error by following the administration instructions for the relevant telephone.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Entry
*940
Code for terminal test
For approximately five seconds, all LEDs blink quickly (ex-
cept for the Service menu LED), all display pixels are acti-
vated, and you can hear a tone.
Guided Maintenance
Description
service.fm
Service
12-37