Signal wire connection
The following maximum ranges (without converter) must be taken into account:
>
4-wire speech: 8 km for 0.6 mm ∅
2-wire speech: 6 km for 0.6 mm ∅
E&M interface type 1 (not for U.S)
TIEL
- 48 V
E
- 48 V
1
4
2 3
5 6
CCT 1: S103
CCT 2: S203
CCT 3: S303
CCT 4: S403
System A
Figure 3-105
E&M Interface Type 1 (Not for U.S.)
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
1E
1M
1ka
1
1kb
1ga
2 3
1gb
S102
(see Table 3-115)
S202
S302
S402
Remote system/transmission
equipment with TIEL
1E
E
1M
1ga
1
4
1gb
1ka
2 3
5 6
1kb
CCT 1: S103
CCT 2: S203
CCT 3: S303
CCT 4: S403
System B
boards.fm
Boards for HiPath 3000
Peripheral Boards
1
2 3
S102
S202
S302
S402