Event Viewer Entries for the HiPath 5000 Server
Event
De-
Error text
fault
trap
1014
X
File open
error
1015
X
Error while
setsockopt.
1016
X
Error while
recvfrom.
1017
X
Error while
sending to
<IP-Adr>
1018
X
Transfer
timed out
12-58
Meaning
Logical TFTP
error; HiPath
3000/5000 dis-
plays a mes-
sage indicating
that frame page
cannot be
opened
Server problem:
Save event
IP socket could
file for error
not be initialized
analysis
HiPath 3000/
Save event
5000 no longer
file for error
replies when
analysis
files are re-
ceived
Logical error
Save event
when sending
file for error
data to HiPath
analysis
3000/5000
No acknowl-
Save event
edgement re-
file for error
ceived/sent
analysis
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
User reaction
Wait 5 minutes then
repeat action.
Shut down and re-
start server.
If error is still
present, restart the
PC.
Connection error,
HiPath 3000/5000
HIP problems.
Check if ping is
working:
If ping is working:
wait 5 mins and re-
start server.
If ping is not work-
ing properly, check
if the "Ping unsuc-
cessful" error mes-
sage appears in the
Event Viewer.
Unrecoverable er-
ror.
Restart server and
report error to ap-
propriate service
support.
Possible connec-
tion interruption or
HiPath 3000/5000
HIP problems.
P31003-H3560-S403-54-7620, 09/05
Cate-
Source
gory
adm HiPath
AllServ
e
adm HiPath
AllServ
e
adm HiPath
AllServ
e
adm HiPath
AllServ
e
adm HiPath
AllServ
e

Advertisement