NQA Event Max: 100
------------------------------------------------------
Run the display nqa alarm command to check the maximum number of alarms that can be
configured and the number of alarms that are configured.
[Huawei-nqa-admin-icmp] display nqa alarm
NQA Alarm Information:
-------------------------------------------------------------------
Admin-Name
-------------------------------------------------------------------
admin
Run the display nqa-agent command to check the status of the test instance configured on the
NQA client.
<Huawei> display nqa-agent
NQA Tests Max:64
NQA Flow
nqa test-instance admin icmp
test-type icmp
destination-address ipv4 11.1.1.32
frequency 5
alarm 10 rtt-average 2 rising-threshold 200 10 falling-threshold 0 10
alarm 20 lost-packet-ratio 2 rising-threshold 10 10 falling-threshold 1 10
nqa status : normal

6.19 Maintaining NQA

This section describes how to maintain an NQA test instance. You can restart the test instance
and clear the statistics on the test result to maintain a test instance.

6.19.1 Restarting NQA Test Instances

If a test instance fails, you can try to restart the test instance in the next test period.
Prerequisites
To restart an NQA test instance, run the following command in the NQA instance view.
Context
Restarting an NQA test instance interrupts the running of tests.
Procedure
Step 1 Run the system-view command, enter the system view.
Step 2 Run the nqa test-instance admin-name test-name command, enter the NQA test instance view.
Step 3 Run the restart command in the NQA instance view to restart an NQA test instance.
----End
Issue 02 (2012-03-30)
Operation-Tag
jitter
Max:1000
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
NQA Event Number: 1
Alarm-Entry
AlarmType
10
Rising
NQA Tests
Number:
NQA Flow Remained:1000
6 NQA Configuration
Event-Entry
10
1
200