Huawei AR150/200 Series Configuration Manual page 198

Enterprise routers
Table of Contents

Advertisement

Huawei AR150&200 Series Enterprise Routers
Configuration Guide - Network Management
Applicable Environment
Trap messages are generated regardless of whether the NQA test is successful or fails. You can
control whether to send trap messages to the NM station by enabling or disabling the trap
function.
NQA supports three types of trap messages as defined in the DISMAN-PING-MIB.
l
l
l
NQA also supports the sending of trap messages to the NM station when the uni-directional
transmission delay or the round-trip transmission delay exceeds the threshold.
l
l
Trap messages carry information such as destination IP address, operation status, destination IP
address of the test packet, minimum RTT, maximum RTT and total RTT, number of sent probe
packets, number of received packets, RTT square sum, and time of the last successful probe.
Pre-configuration Tasks
Before configuring the trap function, complete the following tasks:
l
l
Data Preparation
To configure the trap function, you need the following data.
No.
1
2
Issue 02 (2012-03-30)
Trap message sent when an NQA probe fails
This message checks whether the probe Echo packets are received.
If the number of packets that have no responses reaches the upper limit, trap messages are
sent to a specified NM station.
Trap message sent when an NQA test fails
This message checks whether the test fails.
If the number of the times that a test fails exceeds the limit, trap messages are sent to a
specified NM station.
Trap message sent when an NQA test is successful
This message checks whether the test is successful.
If Echo packets are received during an NQA test, trap messages are sent to a specified NM
station.
For all tests supporting traps, if the round-trip transmission delay exceeds the threshold and
the trap function is enabled, trap messages are sent to the NM station with the specified IP
address.
For all the Jitter tests, if the uni-directional transmission delay exceeds the threshold and
the trap function is enabled, trap messages are sent to the NM station with the specified IP
address.
Configuring routes between the NQA client and the NM station
Creating an NQA test and configuring related parameters correctly
Data
Administrator name and test name
NQA events that trigger the trap function
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
187

Advertisement

Table of Contents
loading

Table of Contents