Checking The Configuration - Huawei AR150/200 Series Configuration Manual

Enterprise routers
Table of Contents

Advertisement

Huawei AR150&200 Series Enterprise Routers
Configuration Guide - Network Management
The destination IP address is configured.
Step 5 Run:
destination-port port-number
The destination port number is configured.
Step 6 (Optional) Perform the following as required to configure other parameters for the UDP test
( For detailed parameter configurations, see the chapter
Parameters
l To configure the source IP address, run the source-address ipv4 ip-address command.
l To configure the source port number, run the source-port port-numbercommand.
l To configure the interval for sending test packets, run the interval seconds interval
l To configure the percentage of the failed NQA tests, run the fail-percent percent command.
l To configure the NQA test packets to be sent without searching the routing table, run the
Step 7 Run:
start
The NQA test is started.
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
l To perform the NQA test after a certain delay period, run the start delay { seconds second
----End

6.11.4 Checking the Configuration

After configuring the UDP test, you can view the test result.
Prerequisites
The configurations of the UDP Test function are complete.
Context
Issue 02 (2012-03-30)
):
command.
sendpacket passroute command.
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } } ]
command.
The test instance is started immediately.
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } } ] command.
The test instance is started at a specified time.
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } } ] command.
The test instance is started after a certain delay.
NOTE
NQA test results cannot be displayed automatically on a terminal. You must run the display nqa results
command to view test results. By the default, the command output contains the records about only the last
five tests.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
Configuring Universal NQA Test
171

Advertisement

Table of Contents
loading

Table of Contents