Configuration Guide - Network Management
l Run:
l Run:
l Run:
l Run:
l Run:
l Run:
----End

6.13.3 Checking the Configuration

After setting universal parameters for NQA test instances, you can view the test result.
Prerequisites
The configurations of the Universal NQA Test Parameters function are complete.
Procedure
Step 1 Run the display nqa-agent [admin-name test-name ] [ verbose ] to view the status of the test
instance configured on the NQA client.
----End
Issue 02 (2012-03-30)
The trap threshold for continuous probe failures is set for the NQA test instance.
timeout time
The timeout period is set for the NQA test instance.
ttl number
The TTL value in the NQA test packet is set.
NOTE
This parameter cannot be configured for DHCP, DNS, and Trace test instances.
tos value
Type of Service (TOS) is set for the test packet.
NOTE
This parameter cannot be configured for DHCP, DNS, and Trace test instances.
tracert-hopfailtimes times
The hop fail times are set for the Trace test instance.
NOTE
This parameter can be configured only for Trace test instance.
tracert-livetime first-ttl first-ttl max-ttl max-ttl
The lifetime is set for the Trace test instance.
NOTE
This parameter can be configured only for Trace test instance.
vpn-instance vpn-instance-name
The VPN instance name is configured for the NQA test instance.
NOTE
This parameter cannot be configured for DNS, and DHCP test instance.