Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
acl acl-number
A basic ACL is created to filter the NM station users that can manage the device.
Step 3 Run:
rule [ rule-id ] { deny | permit } source { source-ip-address source-wildcard |
any }
A rule is added to the ACL.
Step 4 Run:
quit
Return to the system view.
Step 5 Run:
snmp-agent mib-view view-name { include | exclude } subtree-name [ mask mask ]
A MIB view is created, and manageable MIB objects are specified.
By default, an NM station has rights to access the objects in the Viewdefault view (1.3.6.1).
l If a few MIB objects on the device or some objects in the current MIB view do not or no
l If a few MIB objects on the device or some objects in the current MIB view need to be
Step 6 Run:
snmp-agent group v3 group-name { authentication | noauth | privacy } [ read-view read-
view | write-view write-view | notify-view notify-view | acl acl-number ]
The read and write permissions are configured for the user group.
l read-view needs to be configured in the command if the NM station administrator needs the
Issue 02 (2012-03-30)
If all the NM stations need to have rights to access the objects in the Viewdefault view
(1.3.6.1), skip the following steps.
If some of the NM stations need to have rights to access the objects in the Viewdefault view
(1.3.6.1), skip Step5.
If all the NM stations need to manage specified objects on the device, skip Step2, Step3,
and Step4.
If some of the NM stations need to manage specified objects on the device, perform all the
following steps.
longer need to be managed by the NM station, exclude needs to be specified in the command
to exclude these MIB objects.
managed by the NM station, include needs to be specified in the command to include these
MIB objects.
read permission in the specified view in some cases. For example, a low-level administrator
needs to read certain data. write-view needs to be configured in the command if the NM
Huawei Proprietary and Confidential