Configuring The Jitter Client - Huawei AR150/200 Series Configuration Manual

Enterprise routers
Table of Contents

Advertisement

Huawei AR150&200 Series Enterprise Routers
Configuration Guide - Network Management
Note that the IP address and port number monitored by the Jitter server should be consistent
with those configured on the client.
----End

6.12.3 Configuring the Jitter Client

This part describes how to configure the client of the jitter test.
Context
Perform the following steps on the NQA client (Jitter client).
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 (Optional) To configure the version number of Jitter packets, run the nqa-jitter tag-version
version-number command in the system view.
If Version 2 is adopted, after collecting the packet loss across a uni-directional link is enabled,
you can find the packet loss across the link from the source to the destination (or from the
destination to the source or from an unknown direction). According to these statistics, the
network administrator can easily detect network faults and malicious attacks.
Step 3 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 4 Run:
test-type jitter
The test type is set to Jitter.
Step 5 Run:
destination-address ipv4 ip-address
The destination IP address is configured.
Step 6 Run:
destination-port port-number
The destination port number is configured.
Step 7 (Optional) Perform the following as required to configure other parameters for the Jitter test
( For detailed parameter configurations, see the chapter
Parameters
l To configure the source IP address, run the source-address ipv4 ip-address command.
l To configure the source port number, run the source-port port-numbercommand.
l To configure the probe times in the NQA test, run the probe-count number command.
Issue 02 (2012-03-30)
NOTE
The system supports the collection of the statistics about the maximum uni-directional transmission delay.
):
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
Configuring Universal NQA Test
174