system-view
The system view is displayed.
Step 2 Run:
nqa-server tcpconnect
The TCP monitoring service is configured.
----End

6.10.3 Configuring the TCP Client

This part describes how to set TCP test parameters.
Context
Do as follows on the NQA client (TCP client):
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type tcp
The test type is set to TCP.
Step 4 Run:
destination-address ipv4 ip-address
The destination IP address is configured.
Step 5 To configure the destination port number, run the destination-port port-numbercommand.
Step 6 (Optional) Perform the following as required to configure other parameters for the TCP test ( For
detailed parameter configurations, see the chapter
Parameters
l To configure the source IP address, run the source-address ipv4 ip-address command.
l To configure the source port number, run the source-port port-numbercommand.
l To configure the interval for sending test packets, run the interval seconds interval
l To configure the percentage of the failed NQA tests, run the fail-percent percentcommand.
Issue 02 (2012-03-30)
ip-address port-number
NOTE
Note that the IP address and port number monitored by the server should be consistent with those configured
on the client.
):