6G-6 CRANKING SYSTEM
1. Magnetic switch
2. Front housing
3. Yoke

UNIT REPAIR OVERHAUL

DISMOUNTING AND REMOUNTING

Use following procedure to remove starter:
1) Disconnect negative battery lead at battery.
2) Disconnect magnetic switch lead wire and battery cable from
starting motor terminals.
3) Remove two starting motor mount bolts.
4) Remove starting motor.
5) To install, reverse the above procedure.

DISASSEMBLY

NOTE:
_ Before disassembling starting motor, be sure to put match
marks at two locations (A & B) as shown in figure left so that
any possible mistake can be avoided.
_ Do not clamp yoke in a vise or strike it with a hammer during
repair operations.
1) Remove protector (if equipped) and magnetic switch.
1. Magnetic switch
2. Protector
NOTE:
Don't disassemble this switch. If defective, replace as a com-
plete assembly.
1. Magnetic switch
2. Spring
3. Plunger