Suzuki 2000 Grand Vitara SQ625 Service Manual page 442

Table of Contents

Advertisement

1. Crankshaft pulley
2. Bolt
3. Wrench
1. Crankshaft pulley
11) Remove generator belt idler pulley.
12) Disconnect radiator outlet hose from thermostat cap.
13) With hoses connected, detach A/C compressor from com-
14) Remove A/C compressor bracket if equipped.
1. Generator belt
idler pulley
2. A / C compressor
bracket
3. Radiator outlet hose
15) Remove crankshaft pulley bolt.
16) Remove crankshaft pulley.
17) Remove timing chain cover.
CLEAN
_ Clean sealing surface on timing chain cover, crankcase, cylinder
block and cylinder head.
Remove oil, old sealant, and dust from sealing surface.
INSPECTION
_ Check oil seal lip for fault or other damage.
Replace as necessary.
NOTE:
When installing new oil seal, tap it in until its surface is flash
with edge of timing chain cover.
To install oil seal, use special tool (bearing installer).
Special Tool
1. Timing chain cover
2. Oil seal
(A): 09913-75510
pressor bracket if equipped.
To lock crankshaft pulley, use special tool (camshaft pulley
holder) with it as shown in figure.
Special Tool
(A): 09917-68221
NOTE:
Be sure to use the following bolt for fixing special tool to
crankshaft pulley.
Bolt size: M8, P1.25, L = 45 mm
Strength: 7T
If it is hard to remove, use special tools (Steering wheel remov-
er and Bearing puller attachment) as shown in figure.
If bolts of steering wheel remover are too long, replace them
with those of suitable length.
Special Tool
(A): 09944-36011
(B): 09926-58010
ENGINE MECHANICAL (J20 ENGINE) 6A4-23