6A1-20 ENGINE MECHANICAL (G16 ENGINE)
1. Tensioner bolt
2. Tensioner
_ Inspect tensioner for smooth rotation.
INSTALLATION
1) Install tensioner plate to tensioner.
Insert lug of tensioner plate into hole in tensioner.
1. Lug
2. Hole
2) Install tensioner and tensioner plate:
Do not tighten tensioner bolt with wrench yet. Hand tighten only
at this time.
Check to ensure that plate movement in arrow direction as
shown in figure causes tensioner to move in the same direction.
If no associated movement between plate and tensioner occurs,
remove tensioner and plate again and reinsert plate lug into ten-
sioner hole.
3. Tensioner plate
3) Check that timing mark on camshaft timing belt pulley is aligned
with "V" mark on cylinder head cover. If not, align two marks by
turning camshaft but be careful not to turn it more than its allow-
able turning range which is described on page 6A1-19.
1. "V" mark
2. Timing mark
by "E"
4) Check that punch mark on crankshaft timing belt pulley is
aligned with arrow mark on oil pump case. If not, align two marks
by turning crankshaft but be careful not to turn it more than its
allowable turning range which is described on page 6A1-19.
1. Arrow mark
2. Punch mark