7.1.14 ntp-service refclock-master

Syntax
ntp-service refclock-master [ ip-address ] [ stratum ]
undo ntp-service refclock-master [ ip-address ]
View
System view
Parameter
ip-address: Specify the reference clock IP address as 127.127.t.u. Here, t ranges from
0 to 37 and u ranges from 0 to 3.
stratum: Specify which stratum the local clock is located at and range from 1 to 15.
Description
Using ntp-service refclock-master command, you can configure an external
reference clock or the local clock as an NTP master clock. Using undo ntp-service
refclock-master command, you can cancel the NTP master clock settings.
By default, ip-address is not specified and stratum defaults to 1.
You can use this command to designate an NTP external reference clock or the local
clock as an NTP master clock to provide synchronized time for other equipment.
ip-address specifies the IP address of an external clock as 127.127.t.u. If no IP address
is specified, the local clock is set as the NTP master clock by default. You can also
specify the stratum of the NTP master clock.
Example
# Set the local clock as the NTP master clock to provide synchronized time for its peers
and locate it at stratum 3.
[Quidway] ntp-service refclock-master 3

7.1.15 ntp-service reliable authentication-keyid

Syntax
ntp-service reliable authentication-keyid number
undo ntp-service reliable authentication-keyid number
View
System view
Huawei Technologies Proprietary
7-11
Chapter 7 NTP Configuration Commands