6.1.7 rmon alarm

Syntax
rmon alarm entry-number alarm-variable sampling-time { delta | absolute }
rising-threshold threshold-value1 event-entry1 falling-threshold threshold-value2
event-entry2 [ owner text ]
undo rmon alarm entry-number
View
System view
Parameter
entry-number: Number of the entry to be added/deleted, ranging from 1 to 65535.
alarm-variable: Specifies the alarm variable with a character string, ranging from 1 to
256, in the OID dotted format, like 1.3.6.1.2.1.2.1.10.1 (or ifInOctets.1).
sampling-time: Specifies the sampling interval, ranging from 5 to 65535 (measured in
seconds).
delta: Sampling type is delta.
absolute: Sampling type is absolute.
rising-threshold threshold-value1: Rising threshold, ranging from 0 to 2147483647.
event-entry1: Event number corresponding to the upper limit of threshold, ranging from
0 to 65535.
falling-threshold threshold-value2: Falling threshold, ranging from 0 to 2147483647.
event-entry2: Event number corresponding to the falling threshold, ranging from 0 to
65535.
owner text: Specifies the creator of the alarm. Length of the character string ranges
from 1 to 127.
Field
packet
(insufficient
Huawei Technologies Proprietary
Chapter 6 RMON Configuration Commands
Description
Number of oversized packets
Number of undersized and CRC error packets
Number of oversized and CRC error packets
Number of CRC error packets
Number of collision packets
Dropping packet events
6-8