Huawei quidway s3526 series Getting Started page 808

Hide thumbs Also See for quidway s3526 series:
Table of Contents

Advertisement

Command Manual - System Management
Quidway S3500 Series Ethernet Switches
undo rmon prialarm entry-number
View
System view
Parameter
entry-number: Specifies the entry number, ranging from 1 to 65535.
alarm-var: Specifies the alarm variable, which can be an arithmetic expression of
several integer MIB node instances. The node can be OID in dotted notation.
alarm-des: Specifies the alarm description with a length ranging from 0 to 0-127;
sampling-timer: Sets the sampling interval, ranging from 10 to 65535 and measured in
seconds.
delta | absolute | changeratio: Specifies the sampling type as delta ratio or absolute
ratio.
threshold-value1: Rising threshold value, specified with a number greater than 0.
event-entry1: Corresponding event number to the upper limit threshold value, ranging
from 0 to 65535.
threshold-value2: Falling threshold value, specified with a number greater than 0.
event-entry2: Event number corresponding to the falling threshold, ranging from 0 to
65535.
forever | cycle cycle-period: Specifies the type of the alarm instance line.
cycle-period specifies the functional cycle of the instance.
owner text: Specifies the creator of the line. Length of the character string ranges from
1 to 127.
Description
Using rmon prialarm command, you can add an entry to the extended RMON alarm
table. Using undo rmon prialarm command, you can cancel an entry from the
extended RMON alarm table.
The number of instances can be created in the table depends on the hardware
resource of the product.
Example
# Delete line 10 from the extended RMON alarm table.
[Quidway] undo rmon prialarm 10