Procedure
Step 1 (Optional) Run:
display device [ slot slot-id ]
The board status is displayed.
Step 2 Power on or off the board.
l Run the follow command in the user view::
power on slot slot-id
The board is powered on.
l Run the follow command in the user view::
power off slot slot-id
The board is powered off.
----End

2.4 Configuring the Alarm Function for Optical Modules

You can choose an appropriate alarm mode for optical modules.
Context
You can configure the alarm thresholds for the power of optical modules to shield unnecessary
alarms.
To check alarm information, diagnostic information, and manufacturing information about an
optical module, run the display transceiver command.
Procedure
l
l
l
Issue 05 (2014-01-16)
(Optional) Run:
display transceiver [ interface interface-type interface-number | controller
controller-type controller-number | slot slot-id ] [ verbose ]
Conventional, manufacturing, and alarm information about the optical module on an
interface is displayed.
Enable/Disable the optical module alarm function.
1.
Run:
system-view
The system view is displayed.
2.
Run:
set transceiver-monitoring { enable | disable
The optical module alarm function is enabled or disabled.
By default, the optical module alarm function is enabled.
Configure alarm thresholds for optical modules.