Inverter Entrance and Inverter Registration Sensor Replacement
6.
1.
Remove the transport unit covers.
Removal.")
2.
Remove the inverter lower exit guide
3.
Remove the bushing securing the inverter gate pawls [B] and lower
them.
4.
Lower the front end of the guide unit [C] (2 screws).
5*
Remove the inverter entrance guide [D] (3 screws) and replace the
inverter entrance sensor
6.
Replace the inverter registration sensor [F] (2 long screws and 1
connector).
Note: Check that the position of the inverter guide spring [G] is correct.
(Refer to "Transport Unit Cover
[A] (2 screws).
(1 screw and 1 connector).
[E]
.
7-45
30 April, '89