Optics Cooling Fan; Anticondensation Heater - Ricoh FT7770 Service Manual

Copier
Table of Contents

Advertisement

30 April, '89

5. Optics Cooling Fan

prevent hot air from building up in
To
the optics cavity, the cooling fan
blows in cool air from outside. This
fan is energized by two thermo-
switches: TS1 and TS-3. TS-1 is un-
der the exposure glass (115 volt units)
or near the lens home position sensor
(220/240 volt units), and TS-3 is be-
side the cleaning unit.
These two thermoswitches operate as
follows:
Optics Thermoswitch
-
ON
O F F 4 5 ° C
-
Cleaning Thermoswitch (TS-3)
-
ON
OFF 40°C
-

6. Anticondensation Heater

When the main switch is off, 100
volts ac is applied to the anticondensa-
tion heater circuit through RA106. If
TS-2
is
on,
heater circuit turns on.
When the main switch is on, RA106
energizes; the anticondensation heater
circuit
i s t h e n c o n t r o l l e d t h r o u g h
SSR-9 on the ac drive board.
TS-2 closes the circuit at 17°C and
opens it at 25° C.
An internal thermofuse guards against
overheating.
It opens at 169°C.
(TS-1)
55°C
55°C
the
anticondensation
2-16