35.
Set the front and rear second scanner positioning clamps.
36.
Adjust the distance between the rear second scanner bracket [A] and
the rear first scanner bracket [B] as shown. (Distance: 120 mm) This is
also part of the coarse horizontal magnification adjustment.
37.
Tighten the front and rear drive wire clamps [C] on the first scanner (1
Allen screw each).
38.
Remove the front and rear second scanner positioning clamps.
39.
Slide the first and second scanners manually several times to ensure
proper movement.
Reassemble the machine except the upper front cover.
40.
41.
Adjust the horizontal magnification ratio. (Refer to "Horizontal Magnifi-
cation Adjustment".)
42. Reassemble.
5-15