A3/11" X 17" Counter Installation - Ricoh FT7770 Service Manual

Copier
Table of Contents

Advertisement

30 April, '89

A3/11" x 17" COUNTER INSTALLATION

1.
Open the left door.
2.
Remove the development unit cover [A] (1 screw) and the jam indicator
cover [B] (3 screws).
3.
Remove the jam indicator bracket [C] (2 screws).
4.
Disconnect the dummy connector from the A3/11" x 17" counter connec-
tor [D].
5.
Set the A3/11" x 17" counter [E] through the
shown.
6.
Connect the A3/11" x 17" counter connector.
7.
Reassemble.
8.
Set SP 4-4 (A3/11" x 17" counter).
9.
Check the counter operation by making an A3
jam indicator bracket as
3-16
/ 11" x 17" copy.

Advertisement