6. ADJUSTMENTS

6.1 IMAGE DENSITY SENSOR/AUTO DENSITY SENSOR
A D J U S T M E N T
The adjustment procedure is the same as in the F21. (See the F21 service
manual, pages 5-28 and 5-77.)
However the variable resistors used for adjustment (VSG, ADS) have been
moved from the Main PCB to the jam indicator board.
NOTE: VSG voltage is displayed
on the LCD.
Half of the VSG voltage
F21:
is displayed.
F22:
The actual VSG voltage
is displayed.

6.2 FUSING UNIT ADJUSTMENT

The strength of the pressure springs has been increased.
23.0 ± 0.5 kg
Spring
(26 mm)
Because of this, the adjustment standard
of the nip band width has been changed.
F21
8.5 ± 0.8 mm
The difference between the front and rear
measurements should be less than 0.4 mm.
F22
F21
29.0 ± 3 kg
(26 mm)
F22
9.5 ± 0.8 mm
15-11
10 August 1990