Appendix
Para-
Parameter
meter
name
No.
Pn307
Speed com-
mand filter time
constant
Pn308
Speed feed-
back filter time
constant
H Torque Control Parameters (From Pn400)
Parameter
Parame-
name
ter No.
Digit
No.
Pn400
Torque
Sets the torque command voltage (TREF) to output
command
the rated torque.
scale
Pn401
Torque
Sets the constant when filtering the internal torque
command
command.
filter time
constant
Pn402
Forward
Forward rotation output torque limit (rated torque
torque limit
ratio).
Pn403
Reverse
Reverse rotation output torque limit (rated torque
torque limit
ratio).
Pn404
Forward
Output torque limit during input of forward rotation
rotation
current limit (rated torque ratio)
external
current limit
Pn405
Reverse
Output torque limit during input of reverse rotation
rotation
current limit (rated torque ratio)
external
current limit
Pn406
Emergency
Deceleration torque when an error occurs (rated
stop torque
torque ratio)
Pn407
Speed limit
Sets the speed limit in torque control mode.
Pn408
Torque
q
0
command
d
setting
1 to
3
Pn409
Notch filter
Sets notch filter frequency for torque command
frequency
Note 1. Explanation for parameters set using 5 digits.
Note 2. Explanation for parameters requiring each digit No. to be set separately.
H Sequence Parameters (From Pn500)
Parameter
Para-
name
meter
Digit
No.
No.
Pn500
Positioning
Sets the range of positioning completed output 1
completion
(INP1).
range 1
Pn501
Position
Sets the number of rotations for position lock during
lock
speed control.
rotation
speed
6-16
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Explanation
Sets constant during filter of speed command
voltage input (REF).
Sets constant during filter of speed feedback.
Explanation (See note 1.)
Name
Set-
Explanation (See note 2.)
ting
Selects
0
Function not used.
notch filter
h fil
1
Notch filter used for torque
function.
commands.
Not used.
0
(Do not change setting.)
Explanation (See note 1.)
Name
Set-
Explanation (See note 2.)
ting
Default
Default
Unit
setting
setting
100/200 V
400 V
40
40
x 0.01 ms
0
0
x 0.01 ms
Default
Default
Unit
setting
tti
setting
tti
100/200 V
400 V
30
30
0.1 V/
rated
torque
40
100
x 0.01
ms
350
800
%
350
800
%
100
100
%
100
100
%
350
800
%
3000
10000
r/min
0000
0000
---
2000
2000
Hz
Default
Default
Unit
setting
tti
setting
tti
100/200 V
400 V
3
7
Command
unit
10
10
r/min
Chapter 6
Setting
Restart
range
power?
0 to
---
65535
0 to
---
65535
Setting
g
Restart
range
power?
?
10 to
---
100
0 to
---
65535
0 to 800
---
0 to 800
---
0 to 800
---
0 to 800
---
0 to 800
---
0 to
---
10000
---
---
50 to
---
2000
Setting
g
Restart
range
power?
?
0 to 250 ---
0 to
---
10000