System Design and Installation
H Wiring External Regeneration Resistance
D R88D-WTA3HL/-WTA5HL/-WT01HL/--WT02HL/-WTA3H/-WTA4H/-WTA5H/-WT01H/-W
T02H/-WT04H
Connect an External Regeneration Resistor between the B1 and B2 terminals.
Servo Driver
D R88D-WT05H(F)/-WT08H(H)/-WT10H(F)/-WT15H(F/H)/-WT20H(F)/-WT30H(F)/
-WT50H(F)
Remove the short-circuit wiring between B2 and B2, and then connect an External Regeneration Resis-
tor between the B1 and B2 terminals.
Servo Driver
D R88D-WT60H(F)/-WT75H(F)/-WT110HF/-WT150HF
Connect an External Regeneration Resistor or an External Regeneration Resistance Unit between the
B1 and B2 terminals.
Servo Driver
3-50
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
External Regeneration Resistor
External Regeneration Resistor
← Remove
External Regeneration Resistor or External Regeneration Resistance Unit
Note When using the R88A-RR22047S, connect the
thermal switch output so that the power supply will
be shut off when open.
Note 1. The short-circuit wiring between B2 and B3 must be
removed.
2. When using the R88A-RR22047S, connect the
thermal switch output so that the power supply will be
shut off when open.
Note When using the R88A-RR22047S, connect the
thermal switch output so that the power supply will
be shut off when open.