Omron OMNUC W Series User Manual page 241

Ac servomotors/servo drivers
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

Operation
Para-
Parameter
meter
name
No.
Pn303
No. 3 internal
speed setting
Pn304
Jog speed
Pn305
Soft start accel-
eration time
Pn306
Soft start de-
celeration time
Pn307
Speed com-
mand filter time
constant
Pn308
Speed feed-
back filter time
constant
H Torque Control Parameters (From Pn400)
Parameter
Parame-
name
ter No.
Digit
No.
Pn400
Torque
Sets the torque command voltage (TREF) to output
command
the rated torque.
scale
Pn401
Torque
Sets the constant when filtering the internal torque
command
command.
filter time
constant
Pn402
Forward
Forward rotation output torque limit (rated torque
torque limit
ratio).
Pn403
Reverse
Reverse rotation output torque limit (rated torque
torque limit
ratio).
Pn404
Forward
Output torque limit during input of forward rotation
rotation
current limit (rated torque ratio)
external
current limit
Pn405
Reverse
Output torque limit during input of reverse rotation
rotation
current limit (rated torque ratio)
external
current limit
Pn406
Emergency
Deceleration torque when an error occurs (rated
stop torque
torque ratio)
Pn407
Speed limit
Sets the speed limit in torque control mode.
Pn408
Torque
q
0
command
d
setting
1 to
3
Pn409
Notch filter
Sets notch filter frequency for torque command
frequency
Note 1. Explanation for parameters set using 5 digits.
Note 2. Explanation for parameters requiring each digit No. to be set separately.
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Explanation
Number of rotations for No. 3 internal setting
Sets rotation speed during jog operation.
Sets acceleration time during speed control soft
start.
Sets deceleration time during speed control soft
start.
Sets constant during filter of speed command
voltage input (REF).
Sets constant during filter of speed feedback.
Explanation (See note 1.)
Name
Set-
Explanation (See note 2.)
ting
Selects
0
Function not used.
notch filter
h fil
1
Notch filter used for torque
function.
commands.
Not used.
0
(Do not change setting.)
Default
Default
Unit
setting
setting
100/200 V
400 V
300
300
r/min
500
500
r/min
0
0
ms
0
0
ms
40
40
x 0.01 ms
0
0
x 0.01 ms
Default
Default
Unit
setting
tti
setting
tti
100/200 V
400 V
30
30
0.1 V/
rated
torque
40
100
x 0.01
ms
350
800
%
350
800
%
100
100
%
100
100
%
350
800
%
3000
10000
r/min
0000
0000
---
2000
2000
Hz
Chapter 4
Setting
Restart
range
power?
0 to
---
10000
0 to
---
10000
0 to
---
10000
0 to
---
10000
0 to
---
65535
0 to
---
65535
Setting
g
Restart
range
power?
?
10 to
---
100
0 to
---
65535
0 to 800
---
0 to 800
---
0 to 800
---
0 to 800
---
0 to 800
---
0 to
---
10000
---
---
50 to
---
2000
4-25