Operation
Pn510
Output signal selection 3 (All
operation modes)
Pn512
Output signal reverse (All operation
modes)
Note Refer to 4-4-3 Important Parameters.
Pn511
Not used.
Setting
---
range
Note Do not change the setting.
H Other Parameters (From Pn600)
Pn600
Regeneration resistor capacity
Setting
0 to Unit
range
type
• If using an External Regeneration Resistor or External Regeneration Resistance Unit, set the regen-
eration absorption amount. Set the regeneration absorption amount for when the temperature rises
above 120°C, not the nominal amount. (Refer to Regenerative Energy Absorption Using External Re-
generation Resistance for details.)
• Perform Un00A (regeneration load monitor) calculations, and A.92 (regeneration overload warning)
and A.32 (regeneration overload alarm) based on the Pn600 setting.
Note If an External Regeneration Resistor or External Regeneration Resistance Unit is not connected,
set Pn600 to 0.
Pn601
Not used.
Setting
---
range
Note Do not change the setting.
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Unit
---
Unit
x 10 W
Unit
---
Default
0000
setting
Default
0000
setting
Default
8888
setting
Default
0
setting
Default
0
setting
Chapter 4
Restart
Yes
power?
Restart
Yes
power?
Restart
No
power?
Restart
No
power?
Restart
No
power?
4-63