Advertisement

Operation
Para-
Para-
Parameter
Parameter
meter
meter
name
name
Digit
No.
No.
No.
Pn122
Not used.
(Do not change setting.)
Pn123
Not used.
(Do not change setting.)
Note 1. Explanation for parameters set using 5 digits.
Note 2. Explanation for parameters requiring each digit No. to be set separately.
H Position Control Parameters (From Pn200)
Para-
Parameter
meter
name
Digit
No.
No.
Pn200
Position
0
control
setting 1
g
1
2
3
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Explanation (See note 1.)
Explanation (See
Name
Setting
Explanation (See note 1.)
Name
Explanation (See note
Set-
ting
Command
0
Feed pulse
pulse
forward/reverse signal:
mode
Positive logic
1
Forward pulse/reverse
pulse: Positive logic
2
90° phase difference (A/B
phase) signal (x1):
Positive logic
3
90° phase difference (A/B
phase) signal (x2):
Positive logic
4
90° phase difference (A/B
phase) signal (x4):
Positive logic
5
Feed
pulses/Forward/reverse
signal: Negative logic
6
Forward pulse/reverse
pulse: Negative logic
7
90° phase difference (A/B
phase) signal (x1):
Negative logic
8
90° phase difference (A/B
phase) signal (x2):
Negative logic
9
90° phase difference (A/B
phase) signal (x4):
Negative logic
Deviation
0
High level signal
counter
1
Rising signal (low to high)
reset
reset
2
Low level signal
3
Falling signal (low to high)
Deviation
0
Deviation counter reset if
counter
an alarm occurs when
reset if an
Servomotor is OFF.
alarm
alarm
1
Deviation counter not
occurs
reset if an alarm occurs
when the
when Servomotor is OFF.
Servomot
Servomot
or is OFF
2
2
Deviation counter reset
Deviation counter reset
only if alarm occurs.
Pulse
0
Command filter for line
command
driver signal input (500
filter
kpps)
selection
l
ti
1
Command filter for
open-collector signal input
(200 kpps)
Default
Default
Default
Default
setting
setting
setting
setting
100/200 V
100/200 V
400 V
400 V
note 2.)
0
0
0
0
Default
Default
setting
tti
setting
100/200 V
400 V
2.)
1011
0000
Chapter 4
Unit
Unit
Setting
Setting
range
range
---
---
---
---
Unit
Setting
g
tti
range
---
---
Restart
Restart
power?
power?
---
---
Restart
power?
?
Yes
4-23

Advertisement

Table of Contents
loading