Operation
Operation Procedure
PR02W
Front panel
operation
key operation
(1 s min.)
(Approx. 1 s later)
(1 s min.)
Note 1. The digits you can manipulate will flash.
Note 2. If this is set to any value other than 0000 or 0001, "Error" will flash for approximately 1 s, and
then the display will return to the original password.
4-11-9 Checking Servomotor Parameters
H Checking Servomotor Parameters (Fn011)
• You can check the type of Servomotor, encoder, etc., that is connected.
System Check Mode
Servomotor parameter
check
4-138
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Display
Press the MODE/SET Key to change to System Check
Mode.
Press the Up or Down Key to set function code Fn010.
(See note 1.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to display the password "P.jjjj."
Press the Up or Down Key to select the password.
0000: Write enabled, 0001: Write prohibited.
Press the MODE/SET Key to set the password. When
setting is complete, "donE" will flash for approximately
1 s.
After displaying "donE," the display will return to
"P.jjjj."
Press the DATA Key (front panel: DATA Key for 1 s min.)
to return to the System Check Mode function code
display.
1 s min.
1 s min.
1 s min.
1 s min.
Chapter 4
Explanation
Servomotor voltage and
Servomotor type displayed.
Servomotor capacity dis-
played
Encoder information dis-
played.
Servo Driver specifica-
tions displayed.