Operation
H Analog Monitor Output Connector (CN5)
• The Analog Monitor Output Connector (CN5) is located inside the top cover of the Servo Driver.
Note There is no top cover on model R88D-WT60H (6kW). Instead, CN5 is to the right of the display
and settings area.
View with upper cover open
Pin No.
Symbol
1
NM
2
AM
3
GND
4
GND
Note 1. Displays status with no change to scaling.
Note 2. Maximum output voltage is ±8 V. Exceeding this value may result in an abnormal output.
Note 3. Output accuracy is approximately ±15%.
H Analog Monitor Output Circuit
4-116
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Analog Monitor Output
Connector (CN5)
CN5 pin distribution (front panel view)
Name
Analog monitor 2
Analog monitor 1
Analog monitor ground
Analog monitor ground
Servo Driver
Driver pin header: DF11-4DP-2DS
Cable connector socket: DF11-4DS-2C
Cable connector contact: DF11-2428SCF
(Manufactured by Hirose.)
Function and interface
Default setting: Speed monitor 1 V / 1000 r/min. (change
using Pn003.1)
Default setting: Current monitor 1 V / rated torque
(change using Pn003.0)
Ground for analog monitors 1 and 2
g
NM (analog monitor 2)
AM (analog monitor 1)
GND (analog monitor ground)
GND (analog monitor ground)