Omron OMNUC W Series User Manual page 240

Ac servomotors/servo drivers
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

Operation
Para-
Para-
Parameter
Parameter
meter
meter
name
name
Digit
No.
No.
No.
Pn201
Encoder
Sets the number of output pulses from the Servo
divider rate
Driver.
Sets the pulse rate for the command pulses and
Pn202
Electronic
gear ratio
Servo Servomotor travel distance.
G1 (nu-
0.01 ≤ G1/G2 ≤ 100
merator)
Pn203
Electronic
gear ratio
G2 (de-
nominator)
Pn204
Position
Sets soft start for command pulse. (Soft start
command
characteristics are for the primary filter.)
filter time
constant 1
(primary fil-
ter)
Pn205
Absolute
Sets the limit to the number of rotations when using
encoder
a Servomotor with an absolute encoder.
multi-turn
limit setting
Pn206
Full
Sets the number of pulses for the full closed-loop
closed-
encoder for one rotation of the motor (note 3)
loop en-
coder
pulse
Pn207
Position
0
control set
control set-
ting 2
1
2 to
3
Pn208
Position
Sets soft start for command pulse. (soft start
command
characteristics are for the linear acceleration and
filter time
deceleration.)
constant 2
Note 1. Explanation for parameters set using 5 digits.
Note 2. Explanation for parameters requiring each digit No. to be set separately.
Note 3. Do not set below 513.
H Speed Control Parameters (From Pn300)
Para-
Parameter
meter
name
No.
Pn300
Speed
command scale
Pn301
No. 1 internal
speed setting
Pn302
No. 2 internal
speed setting
4-24
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Explanation (See note 1.)
Explanation (See note
Name
Set-
ting
Selects
0
Primary filter (Pn204)
position
position
1
Linear acceleration and
command
deceleration (Pn208)
filter.
Speed
0
Function not used
command
input
input
switching
1
REF used as feed-forward
(during
input
position
control)
Not used.
0
(Do not change setting.)
Explanation
Sets the speed command voltage (REF)
Number of rotations for No. 1 internal setting
Number of rotations for No. 2 internal setting
Default
Default
Default
Default
setting
setting
setting
setting
100/200 V
100/200 V
400 V
400 V
2.)
1000
16384
4
4
1
1
0
0
65535
65535
16384
16384
0000
0000
0
0
Default
Default
setting
setting
100/200 V
400 V
1000
600
100
100
200
200
Chapter 4
Unit
Unit
Setting
Setting
Restart
Restart
range
range
power?
power?
pulse/
16 to
Yes
rotation
16384
---
1 to
Yes
65535
---
1 to
Yes
65535
x 0.01 ms
0 to 6400
---
rotations
0 to
Yes
65535
Command
25 to
---
unit
65535
---
---
Yes
x 0.01 ms
0 to 6400
---
Unit
Setting
Restart
range
power?
0.01 v/No.
150 to
---
rated
3000
rotations
r/min
0 to
---
10000
r/min
0 to
---
10000

Advertisement

Table of Contents
loading

Table of Contents