System Design and Installation
H Terminal Block Wiring Procedure
Connector-type Terminal Blocks are used for Servo Drivers of 1.5 kW or less (R88D-WTA3Hj to R88D-
WT15Hj). The procedure for wiring these Terminal Blocks is explained below.
Connector-type
Terminal Block
1. Remove the Terminal Block from the Servo Driver.
!
Caution
The Terminal Block must be removed from the Servo Driver before being wired. The
Servo Driver will be damaged if the wiring is done with the Terminal Block in place.
2. Strip the covering off the ends of the wires.
Prepare wires of the right sizes, according to the tables provided under Terminal Block Wire Sizes
above, and strip off 8 or 9 mm of the covering from the end of each wire.
3. Open the wire insertion slots in the Terminal Block
There are two ways to open the wire insertion slots, as follows:
S Pry the slot open using the lever that comes with the Servo Driver (as in Fig. A).
S Insert a flat-blade screwdriver (end width: 3.0 to 3.5 mm) into the opening for Servo Driver installa-
tion, and press down firmly to open the slot (as in Fig. B).
3-20
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
210-120J Lever
(Wago Company of Japan Ltd)
Fig. A
(Example: R88D-WT01H)
8 to 9 mm
Chapter 3
Fig. B

Advertisement