Omron OMNUC W Series User Manual page 330

Ac servomotors/servo drivers
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

Operation
D Input Signal Monitor Contents (Un005)
Indicator No.
Input terminal
1
CN1-40
2
CN1-41
3
CN1-42
4
CN1-43
5
CN1-44
6
CN1-45
7
CN1-46
8
CN1-4
Note 1. The vertical 7-segment LED is divided into two segments, upper and lower, which together
comprise one pair to display the ON/OFF status of a single input signal. When an input signal
is OFF (high level), the top LED is lit, and when the signal is ON (low level), the bottom LED is
lit.
Note 2. Refer to 4-4-3 Important Parameters for input signal allocation.
D Output Signal Monitor Contents (Un006)
Indicator No.
Output terminal
1
CN1-31, 32
2
CN1-25, 26
3
CN1-27, 28
4
CN1-29, 30
5
CN1-37
6
CN1-38
7
CN1-39
Note 1. The vertical 7-segment LED is divided into two segments, upper and lower, which together
comprise one pair to display the ON/OFF status of a single output signal. When an output
signal is OFF (high level), the top LED is lit, and when the signal is ON (low level), the bottom
LED is lit.
Note 2. Refer to 4-4-3 Important Parameters for input signal allocation.
D Input Pulse Counter (Un00C) and Feedback Pulse Counter (Un00d) Contents
• Input Pulse Counter (Un00C) and Feedback Pulse Counter (Un00d) monitor values are displayed as
8-digit hexadecimal (32-bit string data).
4-114
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
LED No.
Signal name (default)
RUN (RUN command)
MING (gain reduction), RDIR (rotation direction command), TVSEL
(control mode switching), PLOCK (position lock command), IPG (pulses
prohibited)
POT (forward rotation prohibited)
NOT (reverse rotation prohibited)
RESET (alarm reset)
PCL (forward rotation current limit), SPD1 (speed selection command 1)
NCL (reverse rotation current limit), SPD2 (speed selection command 2)
SEN (sensor ON)
LED No.
Signal name (default)
ALM (alarm)
INP1 (positioning completed output 1), VCMP (speed conformity)
TGON (Servomotor rotation detection)
READY (servo ready)
ALO1 (alarm code output 1)
ALO2 (alarm code output 2)
ALO3 (alarm code output 3)
OFF (high level)
(top is lit)
OFF (high level)
(top is lit)
Chapter 4
ON (low level)
(bottom is lit)
ON (low level)
(bottom is lit)

Advertisement

Table of Contents
loading

Table of Contents