Vista 1 Digital Mixing System
GPIO Inputs
Ext. Supply
5...24 VDC
i
LED
Ext. GND
Negative Common, Ext. Supply
13
25
Solder/Crimp View
(or Socket View)
GPIO Outputs
2-10 Desk Operation
The control inputs (GPI Xa/b) are completely independent and electrically
isolated. They may be used either with the internal +5 V DC supply voltage,
or with external voltages of 5...24 V DC, regardless of the polarity.
Int. Supply (VCC)
Desk
i
LED
Int. GND
Negative Common, Int. Supply
GPI 1-8 (25-pin D-type, female, UNC 4-40 thread)
Pin
Signal 'GPI 1-8'
1
GPI 1a
2
GPI 2a
1
3
GPI 3a
4
GPI 4a
5
GPI 5a
14
6
GPI 6a
7
GPI 7a
8
GPI 8a
9-13
GND (0 V)
The control outputs (GPO Xa/b) are completely independent and electri-
cally isolated relay contacts, closed if active. They may be used either with
the internal +5 V DC supply voltage (VCC) and the internal ground, or with
external voltages within the limits given in the table below. So when using
an external supply, it is irrelevant wheter the load is connected between + or
GND and one of the relay contacts, regardless of the polarity of the external
supply voltage.
Ext.
Supply
Load
(Lamp)
Ext. GND
Switching Power
Switching Voltage
Switching Current
Contact Resistance
The +5 V DC supply voltage and the ground (GND) terminals, together with
the relay contacts, may be used to generate an output signal. Using an external
supply together with the relay contacts is possible as well.
The total current supplied by all VCC (+5 V DC) pins of the GPI / GPO con-
!
nectors must not exceed 400 mA.
SW V5.3
Ext. Supply
5...24 VDC
Desk
i
LED
Ext. GND
Positive Common, Ext. Supply
Desk
Ext. Supply
Contact Rating (max. Values)
62.5 VA / 30 W
50 V AC or DC
1 A
max. 100 mW at 6 V DC / 1 A
Int. Supply (VCC)
Desk
i
LED
Int. GND
Positive Common, Int. Supply
Pin
Signal 'GPI 1-8'
14
GPI 1b
15
GPI 2b
16
GPI 3b
17
GPI 4b
18
GPI 5b
19
GPI 6b
20
GPI 7b
21
GPI 8b
22-25 VCC (+5 V / 600 mA max.)
Int. Supply (VCC)
Load
(Lamp)
Int. GND
Int. Supply
Document generated: 18.04.17