Document generated: 18.04.17
When using the fold button to go back to the normal CHANNEL VIEW, the
individual input gains are kept and the main input gain control will then just
apply an offset to the individual gains.
note :
Eventhough there is now a combination of two gain controls per channel-leg,
the resulting digital gain range remains +/- 24 dB. This is visualized in the
blockdiagram below.
Separate L Gain and R Gain levels are available for all three selectable inputs
of the stereo channel (In1, In2, Gen).
IN 1L
IN 1R
IN 2L
IN 2R
GEN L
GEN R
SW V5.3
Vista 1 Digital Mixing System
DIG 1
GAIN
CTRL
L GAIN
R GAIN
DIG 2
GAIN
CTRL
L GAIN
R GAIN
GEN
GAIN
CTRL
L GAIN
R GAIN
INP
SEL
Parameters 3-57