Source Selection box:
Load button:
Apply button:
Save and Save As... buttons:
OK and Cancel buttons:
Monitor File Name entry box:
Application Progress indicator:
Applied and Saved Status boxes:
4.7.8

Settings: Enable Monitoring Setup-Mode

4.7.9

Settings: Reinitialize Monitoring

Document generated: 18.04.17
This box displays a list of digital sources of a specific type that are available
for assignment to loudspeaker feeds.
This button brings up a familiar Windows box from which an existing monitor
configuration file can be loaded.
This button applies the current monitor configuration file to the Vista. This is
handy when testing a recently edited file or recalling a previously saved file.
The Save button allows a previously saved monitor configuration file to be
updated after editing. The Save As... button allows a new file to be named
and created.
The OK button accepts the current monitor setup and closes the window. Cli-
cking OK does not apply or save the monitor configuration file. The Cancel
button exits the monitor setup screen.
This field is used to enter a name for a new monitor Configuration.
This meter displays the progress of the loading of the monitor configuration
file when it is applied to the console.
These boxes display the status of the current monitor configuration file. If
checked, the current file is applied to the console and/or saved.
To create a new monitor configuration file:
• First open the Monitoring Setup utility from the Monitor section of the
SysAdmin menu.
• Select the desired Assignable Source Selector panel and key, using the lists
on the left.
• Select a source type and source from the lists on the right.
• Highlight the selected source and click on the double-arrow (<<) button
next to the desired loudspeaker feed in the Selection boxes. The source
name will appear in the selected location. Once a key is selected, its name
may be changed using the Display Name field.
• Repeat these steps to complete the necessary assignments. Once finished,
the new file can be saved and applied to the console.
Please note that the edited file must be applied to the console before it takes
effect.
Existing monitor configuration files can be edited by recalling them with the
Load button and using the procedures described above.
To allow access to the speaker calibration, the Enable Setup function must
be enabled. Please refer to
This action will reinitialize the monitor system and reload the last used moni-
tor configuration file. The monitors will mute during this operation.