Technical Details; Vista I/O Sharing Setup - Studer Vista 1 Operating Instructions Manual

Digital mixing system
Hide thumbs Also See for Vista 1:
Table of Contents

Advertisement

Vista 1 Digital Mixing System
8.5

Technical Details

8.5.1

Vista I/o sharing setup

ConfigTool for DNet Applications
##########################################################################
#
# container.ini: Necessary for initialization of each container (.exe)
#
# Digital Mixing Console: VISTA
# Studer Professional Audio GmbH, Regensdorf, Switzerland
#
# Last modification
# Compatible with OATreeLib : V2.1
# Author
: SIA
#
# Rules:
# ======
# - always leave one blank before and after the ‹=› (e.g. systemid=1 NO!)
# - never change the left expression
# - the right expression of systemid, containerid, systemname
# and containername MUST be defined
#
##########################################################################
# The systemid identifies the mixing console system to which this container
# belongs to. The systemid is a unique number within a network.
# The serial number must be in the range 1...255
systemid = 36
 this must be a unique number
# The systemname identifies the mixing console system in a readable way
# and must be unique within a company resp. network. It is recommended
# not to use more than 8 characters due to visualization aspects.
# «Undefined» is not allowed!
systemname = «ConfigTool»
8-10 RELINK
For configuring the tie lines necessary for I/O Sharing on a Vista system, we
use the ConfigTool for DNet Applications known from the OnAir product
range. This program now needs to be installed on the Vista control computer
(C:\Release ConfigTool\ConfigTool.exe). In the same folder there needs to be
a file named container.ini with setup information for this DNet ConfigTool.
Here is an example of a DNet ConfigTool container.ini file:
: Sep, 1st 2006
 the name of the system
SW V5.3
Document generated: 14.04.17

Advertisement

Table of Contents
loading

Table of Contents