CMP MIX on/off
CMP ReL Rotary
CMP aTCK Rotary
CMP RTIo Rotary
eXP / GaTe Mode Rotary
eXP / GaTe ReL Rotary
eXP / GaTe aTCK Rotary
eXP RTIo Rotary
eXP / GaTe hold Rotary
3-36 Parameters
'on' activates the CMP MIX function; 'off' selects the compressed signal
only.
When the CMP MIX function is set to 'on', the ratio of the dry (original) to
the wet (compressed) signal depends on the selected mix ratio. In other words,
mixing between the original and the compressed signals is possible.
The compressor release time can be adjusted within a 5 ms to 5 s range.
The compressor attack time can be adjusted in steps within a 200 µs through
250 ms range.
The compressor ratio can be adjusted from 1:1 (no com pression) through 40:1
(very heavy compression).
Used for selecting either the expander or the gate function for the vintage
dynamics section. The threshold, release, attack and hold parameters of
expander and gate are adjusted in common; they cannot be set individually.
The expander/gate release time can be adjusted within a 5 ms through 5 s
range.
The expander / gate attack time can be adjusted within a 0.5 through 5 ms
range.
The expander ratio can be adjusted from 1:1 (no expansion) through 1:40
(very heavy expansion).
The expander / gate hold time can be adjusted within a 0 through 2 s range.