Config:) Aupc - Comtech EF Data SLM-5650A Installation And Operation Manual

Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

7.2.3.4

(CONFIG:) AUPC

You must first go to the (CONFIG:) MODE submenu and set the modem type as
AUPC in order to select this menu.
AUPC: Local
Logging
Use the  arrow keys to select Local, Remote, ASYNC, or Logging. Press [ENT].
(CONFIG:) AUPC  Local
Local AUPC: Enable: Off Power Settings
Target Setting
Use the arrow keys to select Enable, Power Settings, Target Setting, or Carrier Loss
Action. Press [ENT].
(CONFIG:) AUPC  Local  Enable
Use the  arrow keys to select to enable AUPC on the local modem as On or Off. Press
[ENT].
(CONFIG:) AUPC  Local Power Settings
Local AUPC Power: Nominal: -10.0 dBm
Min: -30.0 dBm
Use thearrow keys to select Nominal:, Min:, or Max:. Press [ENT].
Typical for each setting, use thearrow keys to select a digit, and then use the 
arrow keys to change that digit. Press [ENT] to finish.
Setting
Nominal:
Min:
Max:
Front Panel Operation
Remote
ASYNC
Carrier Loss Action (E)
Max: -05.0 dBm
Nominal Output Power:
-40 to +10 dB.
Minimum Output Power:
-40 to +10 dB.
Maximum Output Power
-40 to +10 dB.
(E)
(E)
Valid Operational Range
7–25
SLM-5650A Satellite Modem
Revision 10
MN-SLM-5650A