10.3.2
Initial Setup – Priority Commands and Queries
Before executing any Modem, Unit, Bulk/Global, AUPC, or Optional Interface commands/queries, initial setup should be accomplished
with these three commands, prioritized as follows: MOM (Highest Priority), RFB, ITF (Lowest Priority). Priority commands are indicated by
shading throughout these sections. Any change to a higher priority parameter can override any of the lower priority parameters.
Controller-to-Target
Instruction Code and
Qualifier
Parameter
Type
Command
Query
Modem
MOM=
MOM?
Operating Mode
Modem RF
RFB=
RFB?
Band
Serial Remote Control
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
1 hex byte
Command or Query.
Sets or returns the Modem Operating Mode in the form x, where:
0 = OM-73
1 = Mil-165A
2 = IESS-308
3 = IESS-309
4 = IESS-310
5 = TURBO
6 = 16QAM
7 = AUPC
8 = RXBURST
9 = TXBURST
A = TURBO-FA
B = RXBRSTFA
C = LDPC
Example: <0001/MOM=0{CR} (sets OM-73 operating mode)
1 byte
Command or Query.
Sets or returns the Modem RF Band in the form x, where:
0 = 70/140 MHz Band
1 = L-Band (950 MHz – 2000 MHz)
Example: <0001/RFB=0{CR} (sets 70/140 Band)
Description of Arguments
10–10
SLM-5650A Satellite Modem
Revision 10
Target-to-Controller
Response to Query
Response to
(see Description of
Command
Arguments)
MOM=x
RFB =x