Comtech EF Data SLM-5650A Installation And Operation Manual page 247

Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

Controller-to-Target
Instruction Code and
Qualifier
Parameter
Type
Command
Query
ASYNC ESC Rx
ARF=
ARF?
Format
AUPC Log
ASI=
ASI?
Sample Interval
Serial Remote Control
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
2 bytes
Command or Query.
Sets or returns Async Format in the form xx, where:
00 = 7 Bits, No Parity, 1 Stop Bit
01 = 7 Bits, Even Parity, 1 Stop Bit
02 = 7 Bits, Odd Parity, 1 Stop Bit
03 = 7 Bits, No Parity, 2 Stop Bits
04 = 7 Bits, Even Parity, 2 Stop Bits
05 = 7 Bits, Odd Parity, 2 Stop Bits
06 = 8 Bits, No Parity, 1 Stop Bit
07 = 8 Bits, Even Parity, 1 Stop Bit
08 = 8 Bits, Odd Parity, 1 Stop Bit
09 = 8 Bits, No Parity, 2 Stop Bits
10 = 8 Bits, Even Parity, 2 Stop Bits
11 = 8 Bits, Odd Parity, 2 Stop Bits
Example: <0001/ARF=0{CR} (sets the ASYNC ESC Rx Format to
7N1)
1 byte
Command or Query.
Sets or returns the sample interval for the AUPC Logging Function in
the form x, where:
x = 0 to 9 in 10-minute steps.
Note: Selecting 0 disables this function.
Example: <0001/ASI=3{CR} (sets the logging inverval to 30 minutes)
Description of Arguments
10–53
SLM-5650A Satellite Modem
Revision 10
Target-to-Controller
Response to Query
Response to
(see Description of
Command
Arguments)
ARF=
ARF=xx
ARF?
ARF*
ARF#
ASI=
ASI=x
ASI?
ASI*
ASI#