9
Refresh the Admin | Upgrade page and verify that the newly-uploaded firmware is reported in the
proper Security Module Bulk Info slot. If not, update the Active Boot Slot Configuration – use the
drop-down menu to select Newest. (This forces the TRANSEC Module to boot using the firmware
with the most recent build date.) Click [Submit] when done.
Firmware Update
Any power failure during this process will result in failure of the
TRANSEC Module.
c.
In the event that an error occurs during the Firmware Application Process, the following
message is displayed:
For troubleshooting purposes, three common reasons for disruption of the Firmware
Application Process are:
Power Failure;
Loss of Ethernet signal (e.g., disconnection of Ethernet cable);
Attempting to load firmware other than the TRANSEC Module bulk firmware
(i.e., FW-0000058x.bin).
d.
Upon successful completion of transfer, the progress bar reads 100%, and the Image
Upgrade Complete message displays: