Controller-to-Target
Instruction Code and
Qualifier
Parameter
Type
Command
Query
Eb/No Alarm
EBA=
EBA?
Equipment ID
N/A
EID?
Serial Remote Control
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
4 bytes
Command or Query.
Sets or returns Eb/No alarm point in dB, with a range between 0.1 and
20 dB.
Resolution = 0.1 dB.
Example: <0001/EBA=12.3{CR}
17 bytes
Query only.
Returns information concerning the equipment identification, and the
option field, in the form aaaabcdefghijklmx where:
aaaa = defines the modem model number (where 565A=SLM-
5650A)
b = Advanced FEC where:
0=None
1=TPC
2=TPC + LDPC
c = Advanced FEC Data Rate where:
0=Base (5,000 kbps)
1=10,000 kbps
2=20,000 kbps
3=51,840 kbps
4=155,520 kbps
5=2,500 kbps
d = Option Card where:
0=None
1=G.703
2=GigaBit Ethernet
3=Reserved
4=Network Processor
5=LVDS
Description of Arguments
10–37
SLM-5650A Satellite Modem
Revision 10
Target-to-Controller
Response to Query
Response to
(see Description of
Command
Arguments)
EBA=
EBA=xx.x
EBA?
EBA*
EBA#
N/A
EID=aaaabcdefghijklm
x