Controller-to-Target
Instruction Code and
Qualifier
Parameter
Type
Command
Query
CnC Power
CRA=
CRA?
Ratio Monitor
CnC Ratio
N/A
CRM?
Monitor
CnC Min/Max
CSD=
CSD?
Search Delay
RTC Date
DAY=
DAY?
Serial Remote Control
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
3 bytes
Command or Query.
Sets or returns CnC Re-acquisition time in the form xxx, where:
xxx = value from 10 to 999.
Note: This is the time wherein CnC will start searching for the delay
and frequency offset if a long duration of unlock occurs.
Example : <0001/CRA=010{CR}
4 bytes
Query only.
When CnC is enabled and locked, returns the ratio, in 1 dB steps,
between the interferer and the desired signal power. Reporting format
varies as follows:
Example 1: >0001/CRM=+02{CR}{LF} (interferer > desired)
(form = sdd, where: s = sign (+/–), dd = value in 1 db steps)
Example 2: >0001/CRM=LT10{CR}{LF} (less than –10 dB)
Example 3: >0001/CRM=GT10{CR}{LF} (greater than +10 dB)
Example 4: >0001/CRM=99.9{CR}{LF} (not locked or CnC not
enabled)
6 bytes
Command or Query.
Sets or returns CnC min/max delay value in milliseconds, in the form
xxxyyy, where:
xxx = min delay value from 0 to 300 ms
yyy = max delay value from 0 to 300 ms
Example: <0001/CSD=010300{CR}
6 bytes
Command or Query.
Sets or returns the date in the form ddmmyy, where:
dd = day of the month (01 to 31),
mm = month (01 to 12)
yy = year (00 to 99)
Example: <0001/DAY=240457{CR} (April 24, 2057)
Description of Arguments
10–36
SLM-5650A Satellite Modem
Revision 10
Target-to-Controller
Response to Query
Response to
(see Description of
Command
Arguments)
CRA=
CRA=xxx
CRA?
CRA*
CRA#
N/A
CRM=xxxx
CSD=
CSD=xxxyyy
CSD?
CSD*
CSD#
DAY=
DAY=ddmmyy
DAY?
DAY*
DAY#