Comtech EF Data SLM-5650A Installation And Operation Manual page 225

Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

Controller-to-Target
Instruction Code and
Qualifier
Parameter
Type
Command
Query
CnC-APC
APC=
N/A
Activate/
Suspend
CnC-APC Max
APL=
APL?
Power Level
Increase
CnC-APC State N/A
APS?
Serial Remote Control
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
1 byte
Command only.
Used to activate or suspend APC operation in form x, where:
0 = no action
1 = Activate APC
2 = Suspend APC
Example: <0001/APC=2{CR} (Suspends APC)
3 bytes
Command or Query.
Sets or returns CnC-APC maximum power level increase in the form
x.x, where:
x.x = value in range from 0.0 to 9.9 dB.
Note: The value is limited by Tx power.
Example: <0001/APL=3.9{CR} (sets APC max power level increase
to 3.9 dB)
2 bytes
Query only.
Returns the state of APC operation in the form xx, where:
00 = APC is not active
01 = No Solution
02 = OK – ReBalance Done
03 = OK(Partial) – CnC Ratio approaches limit
04 = OK(Partial) – Local power approaches minimum value (IF)
05 = OK(Partial) – Local power approaches minimum value (L-
Band)
06 = OK(Partial) – Local power approaches maximum value
07 = OK(Partial) – Local power approaches limit set by max
power level increase
08 = OK(Partial) – Distant power approaches minimum value (IF)
09 = OK(Partial) – Distant power approaches minimum value (L-
Band)
10 = OK(Partial) – Distant power approaches maximum value
Description of Arguments
10–31
SLM-5650A Satellite Modem
Revision 10
Target-to-Controller
Response to Query
Response to
(see Description of
Command
Arguments)
APC=
N/A
APC?
APC*
APC#
APL=
APL=x.x
APL?
APL*
APL#
N/A
APS=xx
MN-SLM-5650A