Comtech EF Data SLM-5650A Installation And Operation Manual page 126

Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

(CONFIG:) Rx  Misc
Rx Misc:
Clk/DataPhase
Eb/No Threshold
Use the arrow keys to select Clk/DataPhase, BitOrdering, or Eb/No Threshold. Press
[ENT].
(CONFIG:) Rx  Misc  Clk/DataPhase
Rx Clock Phase: Normal
Data Phase: Normal
Use the arrow keys to select Rx Clock Phase or Data Phase. Press [ENT]. For
either, use the  arrow keys to select Normal or Invert. Press [ENT].
(CONFIG:) Rx  Misc  BitOrdering
BPSK Bit Ordering: Standard
Use the arrow keys to select BPSK Bit Ordering (for BSPK compatibility) as
Standard or Non-Standard. Press [ENT].
(CONFIG:) Rx  Misc  Eb/No Threshold
Eb/No Threshold: 00.1 dB
This sets an Eb/No threshold. When the received carrier Eb/No is less than the threshold
value, the Rx threshold alarm is set.
Use the  arrow keys to select a digit, and then use the  arrow keys to change
that digit. The valid range is 0.1-20 dB (in 0.1 dB steps). Press [ENT].
(CONFIG:) Rx  CnC
Carrier-in-Carrier(CnC):
Acquisition
Use the arrow keys to select Mode, Acquisition, or SearchDelay. Press [ENT]. If Mode is
selected, use the  arrow keys to select either On or Off. Press [ENT].
Front Panel Operation
BitOrdering
(E)
(E)
Non-Standard
(E)
(E)
Mode:Off
SearchDelay
(E)
7–20
SLM-5650A Satellite Modem
Revision 10
MN-SLM-5650A

Advertisement

Table of Contents
loading

Table of Contents